xenopapers.blogg.se

Disk utility mac incorrect size for logicsl volume
Disk utility mac incorrect size for logicsl volume











The default is 64 MB for PERC 4/SC and PERC 4/DC.Ī larger stripe size provides better read performance, especially if your computerĭoes mostly sequential reads. You can set the stripe size to 2 KB, 4 KB, 8 KB, 16 KB, 32 KB, 64 KB, or 128 KB. Stripe Size specifies the size of the segments written to each drive in a RAID 1, 5, or 10 logical drive.

disk utility mac incorrect size for logicsl volume

RAID 50 requires at least six physical drives. RAID 10 requires at least four physical drives. RAID 5 requires at least three physical drives. RAID 1 requires exactly two physical drives. RAID 0 requires one or more physical drives. The number of physical drives in a specific array determines the RAID levels that can be implemented with the array. Table 5-1 Logical Drive Parameters and Descriptions Parameter Table 5-1 contains descriptions of the logical drive parameters. NOTE: In Cluster mode, PERC 4/DC allows only write-through as the write policy. This section describes the logical drive parameters and default settings for PERC 4/SC and PERC 4/DC and provides procedures for the configuration

  • Define logical drives using the space in the arrays.
  • Designate hard drives as hot spares (optional).
  • See Selecting a Configuration Method in this section for more information.
  • Select a configuration method to create arrays using the available physical drives.
  • Perform the following steps to configure arrays and logical drives: If you do not press within a few seconds of the prompt, the system continues the boot procedure.Īfter you press, the Management Menu screen displays. Press to Enable BIOS Configuration Utilityįor each PERC controller in the host system, the firmware version, dynamic random access memory (DRAM) size, and the status of logical drives on that controller display. HA -0 (Bus 1 Dev 6) Type: PERC 4 Standard FW x.xx SDRAM=128MBĠ Logical Drives found on the Host AdapterĪdapter BIOS Disabled, No Logical Drives handled by BIOS When the host system boots, hold the key and press the key when the following appears:

    disk utility mac incorrect size for logicsl volume

    Verify that the redundancy data in logical drives using RAID level 1 or 5 is correct.Access controllers, logical drives, and, physical drives individually.Configure physical arrays and logical drives.This section describes the procedures used to perform the following: The BIOS Configuration Utility is a character-based utility than you can run by pressing when the system boots. Is independent of the operating systems on your computer. Because the utility resides in the PERC 4 BIOS, its operation The BIOS Configuration Utility configures disk arrays and logical drives. Starting the PERC 4 BIOS Configuration Utility PERC 4 BIOS Configuration Utility: Dell™ PowerEdge™ Expandable RAID Controller 4/SC and 4/DC User's Guideīack to Contents Page PERC 4 BIOS Configuration Utilityĭell™ PowerEdge™ Expandable RAID Controller 4/SC and 4/DC User's Guide













    Disk utility mac incorrect size for logicsl volume